1
2
沒(méi)有這方面的要求的,這是一種并線吧
3
是并排線,你是否有UL2468的安規(guī)資料,請(qǐng)發(fā)一份給我好嗎?
Email:heqy@milestome-mec.com
4
5
6
AWM 2468是并線,UL標(biāo)準(zhǔn)中無(wú)彎曲要求,次線一般用與一些家用電器的插頭連接線;當(dāng)然,如果客戶的使用條件比較特殊,要求彎曲也可以,但客戶要提供彎曲的具體條件,如搖擺頻率,擺角,負(fù)重,R角,次數(shù),這樣才能做彎曲實(shí)驗(yàn).
7
UL 758中的 STYLE 2468
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 2 Page 2468 Issued: 1968-05-07
Style 2468 Flat Ribbon-Type Cable.
______________________________________________________________________________
Rating 80°C, 300 Volts.
______________________________________________________________________________
Conductor 2-150, Nos. 32-16 AWG. Tinned or bare, solid or stranded
copper, conductors laid parallel and in one plane. Same
or mixed AWG.
______________________________________________________________________________
*Insulation Each conductor has a nominal 15 mils wall or heavier
thermoplastic (PVC). This forms a flat cable with a
single row of conductors having a 1/2 in. maximum width
web between insulated conductors. The nominal and minimum
insulation thickness along the ripped edges for each
conductor shall be 15 and 13 mils, respectively.
______________________________________________________________________________
Shield Optional.
______________________________________________________________________________
Covering (Optional) PVC, 5 mils min. at any point 80 mils max.
______________________________________________________________________________
Standard Appliance Wiring Material UL 758.
______________________________________________________________________________
Instructions Detailed Examination.
*to UL Tensile Strength and Elongation of Insulation.
*Representative Spark Test.
______________________________________________________________________________
UL (4) Detailed Examination.
*Counter-Check (4) Tensile Strength and Elongation of Insulation.
Program (4) Heat Shock.
(4) Cold Bend.
(4) Deformation.
(12) Horizontal Flame Test.
______________________________________________________________________________
Marking General.
______________________________________________________________________________
Use Internal wiring of Appliances; or internal wiring of
Appliances where exposed to oil at a tempera-ture not
exceeding 60°C or 80°C, whichever is applicable.
8
謝謝,各位的回復(fù)!!!!
不過(guò)還有一個(gè)問(wèn)題,一般線材是參照哪個(gè)標(biāo)準(zhǔn),是UL758還是UL1581或其它
9
UL線的相關(guān)要求你可以在相應(yīng)的Style page中找到哈,像 cuijiude 的回復(fù)中的就是2468的相關(guān)要求咯
里面已經(jīng)提到咯 Standard Appliance Wiring Material UL 758.
10
11
12
應(yīng)是線套或DC頭的彎曲試驗(yàn), 它和電線插頭的結(jié)構(gòu)有關(guān)
13
主要是針對(duì)SR及DC PLUG 模的實(shí)驗(yàn).
應(yīng)該和模具結(jié)構(gòu)也有關(guān)系.
14
15
沒(méi)聽(tīng)過(guò)UL2468線要搖擺測(cè)試的,電子線的規(guī)格在論壇上就找得到,很多的,你耐心點(diǎn)找一下就可以找到
16

17
可能你的客戶將2468的雙并線用在做手機(jī)充電器插頭上,你只要按照UL標(biāo)準(zhǔn)要求做一般搖擺實(shí)驗(yàn)都可以通過(guò),我曾遇到這樣的客戶。我就這樣做的,不只大俠們認(rèn)為如何?請(qǐng)指正。
18