| UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL | ||||
| Subj.758 | Section 1 | Page 10934 | Issued:2005-01-27 |
| Revised:2008-05-27 | |||
| Style 10934 | Jacketed Cable. | |
| Rating | 80 deg C, 300 Vac, Cable flame, Oil Resistant 60 deg C (optional). |
| Conductor | 32 AWG - 2 AWG solid or stranded round, tinned or bare copper. |
| Insulation | Labeled or complying with manufacturer's AWM procedure. |
| Assembly | Nonmetallic fibrous mechanical strength member may be provided under jacket. Cable may be in the form of helix. |
| Shield | Optional. |
| Jacket | TPU. 33 mils min average, 26 mils minimum at any point. |
| Standard | Appliance Wiring Material UL 758. |
| Marking | General. |
| Use | Internal wiring or external interconnection of electric or electronic equipment, or Internal wiring or external interconnection of electric or electronic equipment where exposed to a temperature not exceeding 80 deg C in air or 60 deg C in oil. 各位大俠: 以上的UL10934 Style Page標(biāo)準(zhǔn)未規(guī)定Covering,是否可以做中層被覆和雙外被的規(guī)格?另外指定Jacket材質(zhì)為TPU,是否可用TPE材料生產(chǎn),因?yàn)門PE也包含TPU材料; 請(qǐng)多多指教!!! 謝謝!!! |
2
既然知道TPE包含TPU,TPU是TPE中的一種,那就只能用TPU了呀
3
4
這個(gè)規(guī)格我們經(jīng)常做,TPU可以分兩次押出
5
……6
第一不能做中被;第二外被只能用TPU。
能不能做雙層外被,我不大清楚,我覺得很有可能是可以做的,不過在算厚度的時(shí)候要把兩層算在一起。
7
分兩層做UL是不允許的,因?yàn)楹苊黠@,分兩層做,那么里邊的那層就算是COVERING,
而covering是STYLE PAGE 里邊有描述的,如果沒有,就不能做。
8
9

謝謝樓上的各位大俠的回復(fù)!!!
10
什么是TPU 什么是TPE?
11
moveitgogo:
我知道CSA的確是這樣要求的,UL是不是這樣要求的不是很清楚.不過雙層外被的話,我相信如果兩層外被用完全一樣的料,將很難看出是押了兩次,而且要把上面那層分離也非常困難.換句話說第一層外被和第二層會(huì)結(jié)合得非常緊密(在不加粉,油之類的隔離物的前提下).
看不看得出來或者會(huì)否分離是另一回事了,呵呵,標(biāo)準(zhǔn)是這樣;
就看你怎么樣不讓UL知道就可以了。