1
2
3
4
本人覺得1015是可以印,但是常用的105C是不可以印上去的,根據(jù)是UL758_12.1
”Insulated conductors with different temperature ratings that are mixed in a given cable complies with
the intent of this requirement when the cable is rated for the lowest temperature rating of any of the
constituent insulated conductors. The insulated conductors shall not be marked with a temperature rating
that is higher than that of the finished cable.“,
上述表明如果芯線的溫度比成品線要高,則芯線的溫度不可以印!
5
alan79114:
本人覺得1015是可以印,但是常用的105C是不可以印上去的,根據(jù)是UL758_12.1
”Insulated conductors with different temperature ratings that are mixed in a given cable complies with
the intent of this requirement when the cable is rated for the lowest temperature rating of any of the
constituent insulated conductors. The insulated conductors shall not be marked with a temperature rating
that is higher than that of the finished cable.“,上述表明如果芯線的溫度比成品線要高,則芯線的溫度不可以!
嗯,我理解也是這樣.
6
芯線不能印105C,UL758規(guī)定“絕緣線芯不得標(biāo)上比成品電纜額定溫度更高的溫度”,具體詳見UL758 12.1
7
8
不強(qiáng)制要求印,印也沒問題啦,
9
10