1
2
3
4
5
UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL |
Subj.758 | Section 1 | Page 10005 | Issued: |
Revised: | |||
Style 10005 | Tape wrapped cable |
Rating | 80 deg C, 30 Vac, Horizontal flame. |
Conductor | 50 AWG minimum, material not specified. |
Insulation | Inner layer: Extruded TFE, PFA, FEP, cellular PE, or solid PE with or without irradiation, 2 mil minimum at any point; or Cellular TFE tape wrap, one or more layers, overall insulation thickness 2 mil minimum at any point. Outer layer: (Optional) Polyester tape, overall thickness 0.2 mil minimum at any point applied with 25 percent overlap and heat sealed. |
Assembly | Insulated conductor with optional inner shield, jacket, optional outer shield and optional outer jacket. |
Shield | Both inner and outer shield are Optional. |
Jacket | Inner jacket - Spirally wrapped, two or more layers of polyester, ETFE, TFE, Cellular TFE, or composite tape, each layer applied with 25 percent overlap (minimum) and heat sealed. Overall thickness minimum 0.2 mil at any point, or extruded PFA, FEP, or PVDF, 1 mil minimum at any point. Outer jacket - (optional) the same as inner jacket. |
Standard | Appliance Wiring Material UL 758. |
Marking | General. |
Use | Internal wiring. |
6
7
8
MIC-L-17標準的RG型號是多少?
9
可以用PFA,FEP或ETFE
10
這根線 我家有做 直接找我買吧
東莞市成佳電線電纜有限公司
主營:UL10005 UL10064 UL1571
聯系王明:13926898087